Carbon is one of the few elements known since antiquity. Several allotropes of carbon with varied physical properties, are widely used in different fields including battery, avation, machining, coating and metallurgy.
Versatility Unleashed: Carbon is a powerhouse of diversity, offering an array of properties from exceptional strength to excellent electrical conductivity. Our carbon products cater to a wide range of industries and applications.
Strength and Lightweight: Carbon's unique combination of strength and lightweight design makes it an excellent choice for applications where both properties are essential, such as aerospace, automotive, and sports equipment.
Electrical Conductivity: Discover carbon products that excel in electrical conductivity, making them ideal for applications in electronics, energy storage, and more.
Customization Possibilities: We understand that each project has distinct requirements. Our customization options allow us to tailor carbon products to your specific needs. Contact us to discuss your specifications.
Carbon Fiber Sheets and Composites: Explore our carbon fiber sheets and composites that offer superior strength-to-weight ratios, making them perfect for lightweight yet robust applications.
Carbon Electrodes: Discover our carbon electrodes designed for high-performance applications in batteries, fuel cells, and other energy storage devices.
Carbon Reinforcements: Elevate your projects with our carbon reinforcements, which enhance the strength and durability of materials like concrete, polymers, and more.
Industry Expertise: With years of experience, we possess deep knowledge of carbon materials and their applications across industries.
Quality Assurance: Our carbon products undergo rigorous testing to meet and exceed industry standards, guaranteeing reliability and performance.
Technical Excellence: Our team of experts is ready to provide technical guidance, address inquiries, and offer personalized recommendations.
Customer-Centric Approach: Your satisfaction is our priority. We collaborate closely with you to fulfill your unique requirements and deliver solutions that match your needs.
Signal Word | N/A |
Hazard Statements | N/A |
Hazard Codes | N/A |
Risk Codes | N/A |
Safety Precautions | N/A |
RTECS Number | FF5250100 |
Transport Information | N/A |
WGK Germany | 3 |
Globally Harmonized System of Classification and Labelling (GHS) | HtmlAgilityPack.HtmlNode,HtmlAgilityPack.HtmlNode,HtmlAgilityPack.HtmlNode,HtmlAgilityPack.HtmlNode,HtmlAgilityPack.HtmlNode,HtmlAgilityPack.HtmlNode,HtmlAgilityPack.HtmlNode,HtmlAgilityPack.HtmlNode |
Product Name: Graphite Plate
CAS #: 7782-42-5
Relevant identified uses of the substance: Scientific research and development
Supplier details:
Stanford Advanced Materials
E-mail: sales@samaterials.com
Tel: (949) 407-8904
Address: 23661 Birtcher Dr., Lake Forest, CA 92630 U.S.A.
Classification of the substance or mixture
Not a hazardous substance or mixture.
GHS Label elements, including precautionary statements
Not a hazardous substance or mixture.
Hazards not otherwise classified (HNOC) or not covered by GHS - none
Substances
Formula: C
Molecular weight: 12.01 g/mol
CAS-No.: 7782-42-5
EC-No.: 231-955-3
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration.
In case of skin contact
Wash off with soap and plenty of water.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water.
Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2) and/or
in section 11
Indication of any immediate medical attention and special treatment needed
No data available
Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Carbon oxides
Advice for firefighters
Wear self-contained breathing apparatus for firefighting if necessary.
Further information
No data available
Personal precautions, protective equipment and emergency procedures
Avoid dust formation. Avoid breathing Vapors, mist or gas.
For personal protection see section 8.
Environmental precautions
Do not let product enter drains.
Methods and materials for containment and cleaning up
Sweep up and shovel. Keep in suitable, closed containers for disposal.
Reference to other sections
For disposal see section 13.
Precautions for safe handling
Further processing of solid materials may result in the formation of combustible dusts. The potential for
combustible dust formation should be taken into consideration before additional processing occurs.
Provide appropriate exhaust ventilation at places where dust is formed.
For precautions see section 2.2.
Conditions for safe storage, including any incompatibilities
Keep container tightly closed in a dry and well-ventilated place.
Specific end use(s)Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Exposure controls
Appropriate engineering controls
General industrial hygiene practice.
Personal protective equipment
Eye/face protection
Use equipment for eye protection tested and approved under appropriate government standards such
as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
Body Protection
Choose body protection in relation to its type, to the concentration and amount of dangerous
substances, and to the specific work-place., The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use
type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and approved
under appropriate government standards such as NIOSH (US) or CEN (EU).
Control of environmental exposure
Do not let product enter drains.
Information on basic physical and chemical properties
Appearance
Form: Powder or solid in various forms
Colour: Black/ Dark grey
Odor
odourless
Odor Threshold
No data available
pH
No data available
Melting point/freezing point
Melting point/range: 3,652 -3,697 °C (6,606 -6,687 °F)-lit.
Initial boiling point and boiling range
No data available
Flash point
No data available
Evaporation rate
No data available
Flammability (solid, gas)
No data available
Upper/lower flammability or explosive limits
No data availableVapor pressure
No data available
Vapor density
No data available
Relative density
No data available
Water solubility
slightly soluble
Partition coefficient: n-octanol/water
No data available
Auto-ignition
temperature
No data available
Decomposition temperature
No data available
Viscosity
No data available
Explosive properties
No data available
Oxidizing properties
No data available
Other safety information
No data available
Reactivity
No data available
Chemical stability
Stable under recommended storage conditions.
Possibility of hazardous reactions
No data available
Conditions to avoid
No data available
Incompatible materials
Strong oxidizing agents
Hazardous decomposition products
Other decomposition products - No data available
In the event of fire: see section 5
Information on toxicological effects
Acute toxicity
LD50 Oral - Rat - female - > 2,000 mg/kg
(OECD Test Guideline 423)
LC50 Inhalation - Rat - male and female - 4 h - 2,000 mg/m3
(OECD Test Guideline 403)
Dermal:
No data available
No data availableSkin corrosion/irritation
Skin - Rabbit
Result: No skin irritation
(OECD Test Guideline 404)
Serious eye damage/eye irritation
Eyes - Rabbit
Result: No eye irritation
(OECD Test Guideline 405)
Respiratory or skin sensitisation
- Mouse
Did not cause sensitisation on laboratory animals.
(OECD Test Guideline 429)
Germ cell mutagenicity
in vitro assay
S. typhimurium
Result: negative
Carcinogenicity
IARC:
No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
ACGIH:
No component of this product present at levels greater than or equal to 0.1% is identified as a
carcinogen or potential carcinogen by ACGIH.
NTP:
No component of this product present at levels greater than or equal to 0.1% is identified as a known
or anticipated carcinogen by NTP.
OSHA:
No component of this product present at levels greater than or equal to 0.1% is identified as a
carcinogen or potential carcinogen by OSHA.
Reproductive toxicity
No data available
No data available
Specific target organ toxicity - single exposure
No data available
Specific target organ toxicity - repeated exposure
No data available
Aspiration hazard
No data available
Additional Information
Repeated dose toxicity - Rat - male - Feed - No observed adverse effect level - 813 mg/kg
RTECS: MD9659600
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.
Toxicity
Toxicity to fish
semi - static test LC50 - Danio rerio (zebra fish) - > 100 mg/l - 96 h
(OECD Test Guideline 203)
Toxicity to daphnia and other aquatic invertebrates
static test EC50 - Daphnia magna (Water flea) - > 100 mg/l - 48 h
(OECD Test Guideline 202)Toxicity to algae
static test EC50 - Pseudokirchneriella subcapitata - > 100 mg/l - 72 h
(OECD Test Guideline 201)Persistence and degradability
No data available
Bioaccumulative potential
No data available
Mobility in soil
No data available
Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
Other adverse effects
No data available
Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company.
Contaminated packaging
Dispose of as unused product.
DOT (US)
Not dangerous goods
IMDG
Not dangerous goods
IATA
Not dangerous goods
SARA 302 Components
No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components
This material does not contain any chemical components with known CAS numbers that exceed the
threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards
No SARA Hazards
Massachusetts/Pennsylvania/New Jersey Right To Know Components
Graphite
CAS-No.: 7782-42-5
Revision Date: 1989-08-11
California Prop. 65 Components
This product does not contain any chemicals known to State of California to cause cancer, birth
defects, or any other reproductive harm.
Safety Data Sheet according to Regulation (EC) No. 1907/2006 (REACH). The above information is
believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The
information in this document is based on the present state of our knowledge and is applicable to the
product with regard to appropriate safety precautions. It does not represent any guarantee of the
properties of the product.
Send us an Inquiry now to find out more Information and the latest prices,thanks!
Please fill in your RFQ details and one of sales engineers will get back to you within 24 hours. If you have any questions, You can call us at 949-407-8904 (PST 8am to 5pm).
Copyright © 1994-2025 Stanford Advanced Materials owned by Oceania International LLC, All Rights Reserved.